14: Advanced Settings
EDS1100/2100 Device Server User Guide 128
2. Enter or modify the following settings:
Table 14-5 CLI Configuration
3. Click Submit
.
Command Line Interface
Configuration Settings
Description
Login Password Enter the password for Telnet access.
Enable Level Password Enter the password for access to the Command Mode Enable level. There is
no password by default.
Quit Connect Line Enter a string to terminate a connect line session and resume the CLI. Type
<control> before any key the user must press when holding down the Ctrl
key. An example of such a string is <control>L.
Inactivity Timeout Set an Inactivity Timeout value so the CLI session will disconnect if no data is
received after the designated time period. Default is 15 minutes. Enter a value
of 0 to disable.
Login String State Select to enable or disable. The login string state controls the display of a
device-specific string when SSH or Telnet connection is established to the CLI.
Login String Enabling the login string state allows the display of the Login string. The login
string cannot exceed 32 characters. By default Login String will be the device
name.
Note: This configuration field appears when Login String State is enabled
above. This Login String setting only applies to SSH or Telnet connections to
the CLI. If the serial line is being used in Command Mode, for CLI access, then
refer to the Line Command Mode section for those applicable settings.
Telnet State Select Disabled to disable Telnet access. Telnet is enabled by default.
Telnet Port Enter the Telnet port to use for Telnet access. The default is 23.
Telnet Max Sessions Maximum number of simultaneous Telnet sessions. The default is 3 and the
maximum is 10.
SSH State Select Disabled to disable SSH access. SSH is enabled by default.
SSH Port Enter the SSH port to use for SSH access. The default is 22.
SSH Max Sessions Maximum number of simultaneous SSH sessions. The default is 3 and the
maximum is 10.