Implemented CIP™ objects
EtherNet/IP objects
130
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.2.4 Ethernet Link Object (246 / 0xF6)
The "Ethernet Link Object" provides general information and status information about the Ethernet
interfaces (IEEE 802.3).
Class attributes
Instance attributes
Note!
Write accesses to writable attributes become effective immediately.
Attribute
ID
Service Name Data type Value
1 Get Revision UINT 3 (0x0003)
2 Get Max. Instance UINT 2 (0x0002)
3 Get Number of Instances UINT 2 (0x0002)
4 Get Optional Attribute List: STRUCT of:
Number Attributes UINT 4 (0x0004)
Optional Attributes ARRAY of
UINT
7 ... 10
(0x0007.0008.0009.000A)
6 Get Max. ID Number Class
Attributes
UINT 0x0007
7 Get Max. ID Number Instance
Attributes
UINT 0x000A
Attribute
ID
Service Name Data type Value
1 Get Interface Speed UDINT Current baud rate
• 10 Mbps
• 100 Mbps
2 Get Interface Flags DWORD Status bits of the Ethernet interface
Instance attribute "Interface Flags"
(attribute 2) ( 131)
3 Get Physical Address ARRAY of
USINT[6]
MAC address of the Ethernet interface
6 Set Interface Control STRUCT of:
Control Bits WORD Control bits for the Ethernet interface
Instance attribute "Control Bits"
(attribute 6, Interface Control) ( 132)
Forced Interface Speed UINT Baud rate [in Mbps] at which the Ethernet
interface is to be operated (C13017
).
Example values:
• 10 = 10 Mbps
• 100 = 100 Mbps
7 Get Interface Type USINT Interface type (transmission medium)
• 0: Unknown interface type
• 1: Device-internal interface (e.g.
embedded switch)
• 2: Twisted pair (e.g. 100Base-TX), Lenze
setting
• 3: Optical fibre (e.g. 100Base-FX)
• 4 ... 255: Reserved