Data transfer
Communication channels
42
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.1 Communication channels
EtherNet/IP transmits parameter data and I/O data between the host system (scanner) and the
inverters (adapters) connected to the fieldbus. The data are transmitted via corresponding
communication channels depending on their time-critical behaviour.
The I/O data channel transmits I/O data by means of "implicit messages".
The inverter is controlled by means of the I/O data.
The transmission of I/O data is time-critical.
I/O data are transmitted cyclically between the host system (scanner) and the inverters
(adapters) (permanent exchange of current input and output data).
The host system (scanner) has direct access to the I/O data (the data are, for example, stored
directly in the I/O area).
To the scanner, up to 10 data words (max. 20 bytes) can be sent.
From the scanner, up to 8 data words (max. 16 bytes) can be sent.
I/O data are not stored in the inverter.
I/O data are e.g. setpoints, actual values, control and status words
The parameter data channel transmits parameter data by means of "explicit messages".
The transmission of parameter data is usually not time-critical.
Examples of parameter data are operating parameters, motor data, and diagnostic information.
The parameter data channel provides access to all Lenze codes.
Parameter changes must be saved via code C00002 of the Inverter Drive 8400 motec.
Note!
The terms "input" and "output" refer to the point of view of the scanner:
Input data is produced by the adapter and consumed by the scanner.
Output data is produced by the scanner and consumed by the adapter.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EtherNet/IP E84DGFCGEJP and is the answer not in the manual?

Lenze EtherNet/IP E84DGFCGEJP Specifications

General IconGeneral
BrandLenze
ModelEtherNet/IP E84DGFCGEJP
CategoryConference System
LanguageEnglish

Related product manuals