Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019 139
Implemented CIP™ objects
Lenze objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.4 Lenze objects
14.4.1 Lenze Class (101 / 0x65)
The "Lenze Class (101 / 0x65)" enables the access to the adjustable error responses to EtherNet/IP
errors which can be set in code C13880
.
Class attributes
Instance attributes
Note
The attributes of this class are described in the EDS file. Using the »RSNetWorx«
Rockwell software, the attributes can thus be directly set under "Parameters" in the
properties dialog of the EtherNet/IP node.
Attribute
ID
Service Name Data type Value
1 Get Revision UINT 2 (0x0002)
2 Get Max. Instance UINT 1 (0x0001)
Attribute
ID
Service Name Data type Value
1 Get No. of supported Attributes USINT 6 (0x0006)
2 Get Attribute List USINT 1 (0x0001) ... 6 (0x0006)
3 Get / Set Reaction on Idle Mode USINT Corresponds to the value in C13880/1
:
• 0 = no response
•1 = error
• 4 = warning locked
4 Get / Set Reaction on Fault Mode USINT Corresponds to the value in C13880/2
:
• 0 = no response
•1 = error
• 4 = warning locked
5 Get / Set Reaction on Expl. Msg. TO USINT Corresponds to the value in C13880/3
:
• 0 = no response
•1 = error
• 4 = warning locked
6 Get / Set Reaction on I/O Timeout USINT Corresponds to the value in C13880/4
:
• 0 = no response
•1 = error
• 4 = warning locked