Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019 43
Data transfer
Telegram types
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.2 Telegram types
The "implicit message" and "explicit message" telegram types are transmitted between the host
system (scanner) and the inverter (adapter).
Implicit messages (I/O data transfer)
"Implicit messages" are transmitted or received according to the producer/consumer principle.
There is one transmitter and no receiver or an optional number of receivers.
The "cyclic I/O data" transmission mode is supported. The scanner and the adapter use "cyclic I/O
data" to generate their data independently of each other, which are then transmitted depending on
a timer. The user must set the value of the timer in the scanner.
Explicit messages (parameter data transfer)
"Explicit messages" serve to configure and parameterise the individual EtherNet/IP nodes.
Two nodes have a client/server relationship:
The client transmits a job (request). The server receives this job and tries to accomplish it. The server
then transmits the requested data (positive response) or an error message (negative response).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EtherNet/IP E84DGFCGEJP and is the answer not in the manual?

Lenze EtherNet/IP E84DGFCGEJP Specifications

General IconGeneral
BrandLenze
ModelEtherNet/IP E84DGFCGEJP
CategoryConference System
LanguageEnglish

Related product manuals