Crane operation
10.4 Operation of the rated capacity limiter
10 - 64 3 302 633 en Operating Instructions GMK5250L
27.09.2017
When rigging For rigging work, you can:
– override the lifting limit switch;
à p. 10 - 83
or
– override the RCL and thus enable a degree of utilisation of up to 110%.
RCL override
• Press the button (1) once – the information
message (2) is displayed.
– Now a degree of utilisation of up to 110% is
enabled.
– If you do not trigger a control lever move-
ment within 10 seconds after the override,
you must press the button (1) again.
– The speed of the movements which
increase the load moment is reduced
to 15%.
Cancelling the override
The override will be cancelled when you:
– press button (1) again, or
– do not activate the control lever for 10 seconds, or
– switch off the ignition.
S
Risk of accidents if the RCL is overridden!
It is not permitted to work with an overridden RCL!
Use this type of override only for rigging.