POWER TRAIN TMS700E SERVICE MANUAL
7-16 Published 01-29-2015, Control # 512-01
After 1000 Hours, or One Year
Visually inspect the exhaust connector. If necessary, tighten
the V-clamps by one full turn of the nuts.
2000 Hours or 2 Years
Tighten the V-clamps by 1 ½ turns of the nuts.
4000 Hours or 4 Years
Tighten the V-clamp by 1 ½ turns of the nuts.
5000 Hours or 5 Years
Remove the V-clamps and gaskets, and replace them with
new gaskets and clamps. Tighten the V-clamps to 9.6 to 11.3
Nm (85 to 100 lb-in) of torque.
ISX Exhaust System
6786
2
3
5
1
ISX Exhaust System
1. Diesel Particulate Filter (DPF)
2. Diesel Exhaust Fluid (DEF) Injector
3. Decomposition Pipe
4. Mounting Band
5. Selective Catalytic Reduction (SCR) Stack
4
Reference Only