Grove Published 01-29-2015, Control # 512-01 9-5
TMS700E SERVICE MANUAL LUBRICATION
9
CARRIER LUBRICATION
1. Engine Crankcase
Lube Type - EO - 15W40
Lube Interval - Check fluid level every 10 hours or daily,
whichever interval occurs first. Drain, fill and replace
filter every 400 hours.
Lube Amount - Capacity
QSM Engine - 36 l (38 qt)
ISX Engine - 44 l (47 qt)
Application - Fill to full mark on dipstick.
2. Engine Cooling System
Lube Type - AFC
Lube Interval - Check coolant level every 10 hours or
daily, whichever interval occurs first. Test and refresh
per instructions in Water Cooling System, page 7-21.
Lube Amount - Capacity
QSM Engine - 54 l (57 qt)
ISX Engine - 75 l (79 qt)
Lube Type - SCA
Lube Interval - Change filter and check SCA levels every
500 hours. Check coolant for contamination every 1000
hours. Test and refresh per instructions in Water Cooling
System, page 7-21.
3. Transmission
Lube Type - SGL-5
Lube Interval - Check fluid level every 500 hours, 6
months, or 14500 km (9,000 mi), whichever interval
occurs first. Drain, fill, and replace filter every 80,000 km
(50,000 mi) or 2 years, whichever interval occurs first.
Lube Amount - Capacity - 19 liters (20 quarts)
Application - Final fluid levels shall be adjusted to
indicating arrows, dipstick markings, or to bottom of fill
plug threads.
4. Pump Drive
Lube Type - SSGL-5
Lube Interval - Check fluid level every 100 hours or
monthly, whichever interval occurs first. Drain and fill
every 500 hours.
Lube Amount - Capacity - 2.4 l (2.5 qt)
Application - Through fill pipe (dipstick pipe) to oil level
mark on dipstick.
5. Pump Drive Shaft
a. U-Joints
Lube Type - EP-MPG
Lube Interval - 250 hours
Lube Amount - Until grease extrudes
Application - 2 grease fittings
b. Spline
Lube Type - EP-MPG
Lube Interval - 500 hours
Lube Amount - Until grease extrudes
Application - 1 grease fitting
6. Clutch Throw-Out Bearing
Lube Type - EP-MPG
Lube Interval - 250 hours
Lube Amount - Until grease extrudes
Application - 1 grease fitting, apply with engine running
for equal distribution of grease
7. Clutch Linkage
Lube Type - EP-MPG
Lube Interval - 500 hours
Lube Amount - Until grease extrudes
Application - 5 grease fittings
CAUTION
Improper filling of the engine coolant system can result in
engine damage.
CAUTION
Axle fluid levels shall be adjusted to bottom of fill plug
threads. Check with crane on level ground, at its normal
ride height; cold or room temperature oil only.
DANGER
Ensure crane is on jacks and wheels are off ground,
parking brakes are set, transmission is in neutral gear,
and an assistant is depressing the clutch pedal before
trying to grease the clutch throw-out bearing. Doing so
allows the transmission input shaft -- shielded by the
transmission’s clutch housing -- to turn and distribute
grease without the other drive shafts turning and posing
further hazards to workers. Allowing crane to move could
cause workers death or serious injuries.
Reference Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove TMS700E and is the answer not in the manual?

Manitowoc Grove TMS700E Specifications

General IconGeneral
BrandManitowoc
ModelGrove TMS700E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals