LUBRICATION TMS700E SERVICE MANUAL
9-10 Published 01-29-2015, Control # 512-01
NOTE: Under normal operating conditions, it is
recommended that hydraulic oil, filters and
breathers be inspected and oils sampled at least
every 3 to 6 months and more frequently for severe
operating conditions. The inspections should be for
air borne and/or ingested particles and water that
deteriorate and contaminate the oil (e.g., oil
appears “milky” or no longer has a transparent
clear to amber color). The return filter by-pass
indicator should be observed daily to determine if
the contaminants content may be high. If the
indicator reaches the red zone or indicates a by-
pass condition, the hydraulic oil must be sampled.
The hydraulic tank breather should also be
inspected to assure that it is not restricting air flow
into and out of the reservoir.
To inspect hydraulic oil, fill a small glass container
with a sample of reservoir oil and another glass
container with fresh oil. Let the samples stand,
undisturbed, for one to two hours and then
compare the samples. If the reservoir oil is heavily
contaminated with water the sample will appear
“milky” with only a small layer of transparent oil on
top. If the “milky” appearance was due to air
foaming, it will dissipate and the oil should closely
match the fresh oil. Should you have any
questions, please contact your distributor or
Manitowoc Crane Care.
After 2000 hours or 2 years of service, an oil
sample should be taken and laboratory analyzed. If
it continues to meet a minimum cleanliness level of
ISO 16/13 (SAE J1165), the service interval can be
increased to 3000 hours or 3 years.
Lube Amount - 134 gal (507 l) (tank only), to the FULL
mark on sight gauge.
Application - Remove the breather; fill through the
breather hole on top of tank; reinstall breather. When
tank is drained, clean the magnetic pipe plug.
Replace breather every 500 hours or 6 months,
whichever interval occurs first.
26. Hydraulic Filter
Drain water trap every 10 hours or daily and change filter
when clear cover is full of fuel.
27. Fuel Filter
Drain water trap every 10 hours or daily and change filter
every 500 hours or 6 months.
28. Air Cleaner Filter
Replace air cleaner filter element when indicator shows
red (0.062 bar (25 inches of water) or indicator is red).
29. Coolant Strainer (Superstructure Cab Heater)
Close the shutoff valves. Unscrew the hex plug and
clean the strainer screen after first 100 hours and every
2000 hours or 12 months thereafter.
SUPERSTRUCTURE LUBRICATION
30. Turntable Gear Box
Lube Type - SSGL-5
NOTE: Remove one valve to equalize the pressure before
checking the swing gearbox oil level. This will keep
the oil from pushing out.
Lube Interval - Check and fill every 50 hours. Drain and
fill after first 250 hours and every 500 hours or 12
months thereafter, whichever interval occurs first.
Lube Amount -
Gearbox - 1.30 l (2.75 pt)
Application - Fill until oil level is at top of sight gauge
31. Turntable Gear and Drive Pinion
Lube Type - EP-OGL
Lube Interval - 500 hours or 6 months, whichever
interval occurs first
Lube Amount - Coat all teeth
Application - Spray on
32. Turntable Bearing
Lube Type - EP-MPG
Lube Interval - 500 hours or 6 months, whichever
interval occurs first
Lube Amount - Until grease extrudes the whole
circumference of the bearing.
Application - 2 grease fittings at the front of the turntable.
Rotate the turntable 90° and apply grease to fittings.
Continue rotating 90° and grease the fittings until the
whole bearing is greased.
32a. Swivel Lock Pin
Lube Type - EP-OGL
Lube Interval - 500 hours or 6 months, whichever
interval occurs first
Lube Amount - Coat pin
Application - Spray on
Reference Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove TMS700E and is the answer not in the manual?

Manitowoc Grove TMS700E Specifications

General IconGeneral
BrandManitowoc
ModelGrove TMS700E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals