Grove Published 01-29-2015, Control # 512-01 9-9
TMS700E SERVICE MANUAL LUBRICATION
NOTE: Figure 9-2 pertains to the differentials and the
planetary hubs and wheel bearings.
19. Rear Rear Axle Differential
Lube Type - SSGL-5
Lube Interval - Check lubricant level every 250 hours
and refill as necessary. Drain, refill, and clean magnetic
drain plug every 80,000 km (50,000 mi) or 2 years,
whichever interval occurs first.
Lube Amount - Capacity - 17.5 l (37 pt) Normal makeup -
less than 0.23 l (0.5 pt).
Application - Fill to bottom of fill plug threads.
20. Rear Axle Brake Slack Adjusters
Lube Type - EP-MPG
Lube Interval - 1000 hours
Lube Amount - Until grease extrudes
Application - 4 grease fittings
21. Rear Axle Brake Camshafts
Lube Type - EP-MPG
Lube Interval - 1000 hours
Lube Amount - Until grease extrudes
Application - 4 grease fittings
22. Outrigger Beams
Lube Type - EP-MPG
Lube Interval - 50 hours or 1 week, whichever interval
occurs first
Lube Amount - Brush on bottom of outrigger beams.
Application - Brush on; 8 places
23. Jack Cylinder Support Tubes
Lube Type - EP-MPG
Lube Interval - 500 hours
Lube Amount - Brush lubrication on ID of jack cylinder
support tubes and wear bands before installing jack
cylinders.
Application -Brush on; 5 places
24. Jack Cylinder Barrels
Lube Type - EP-MPG
Lube Interval - 50 hours or 1 week, whichever interval
occurs first
Lube Amount - Fully extend outriggers and brush
lubricant onto cylinder barrels.
Application - Brush on; 5 places
25. Hydraulic Reservoir
Lube Type - HYDO
Lube Interval - Check fluid level every 10 hours or daily,
using sight gauge on side of tank, with boom retracted
and in boom rest and all outrigger cylinders retracted;
drain and refill as necessary. Replace oil every 2000
hours or 2 years, whichever interval occurs first.
NOTE: Environmental and other conditions can
dramatically affect the condition of hydraulic oil and
filters. Therefore, specific intervals for servicing/
changing hydraulic oil, filters and hydraulic tank
breathers cannot be set. However, it is imperative
for the continued satisfactory performance of
Grove cranes that inspections be performed on the
basis of how and where each crane is used. Air
borne and ingested contaminants can significantly
reduce the life of oil and the condition of hydraulic
oil filters and tank breathers.
CAUTION
Use of non-semi-synthetic lubricant may damage
components and/or invalidate published lubrication
intervals.
Axle fluid levels shall be adjusted to bottom of fill plug
threads. Check with crane on level ground, at its normal
ride height, cold or room temperature oil only. A 30 minute
drain-down time is required before checking fluid level if
crane has been recently moved.
If the makeup amount is substantially more than 0.23 l
(0.5 pt) check for leaks.
___ Correct: Lube level at bottom of
filler hole.
- - - Incorrect: Lube level below filler
hole.
FIGURE 9-2
Reference Only