Technical Information
113
G 1xxx/G 2xxx
6. Remove the drip pan. See Section 010-4.2.
7. Pull off the float switch.
8. Disconnect its plug connections.
4.27 Dismantling the Filter Combination
Note:
During reassembly, a locking piece must be installed to prevent the filter
combination from falling apart; see Section 050-4.29.
As an alternative, the microfine filter and the handle piece (crown coarse
filter) must be replaced together; see Section 050-4.28.
1. Open the filter cap.
2. Place a screwdriver on the retaining clip spring and press against it; see
Figure 050-25.
3. Turn the handle clockwise and release the filter combination clip
connection.
Figure 050-25: Combination Filter
Note:
If the filter combination is already held together with a locking piece, this
must be broken open and removed.