172
G 1xxx/G 2xxx
Function Programming Display
Appliance width setting
1
Press the Delay Start
button 35x. The "Delay
Start" LED flashes 3x
slowly and 5x rapidly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
24” (60cm); p1 = 18” (45cm).
Appliance height setting
1
Press the Delay Start
button 36x. The "Delay
Start" LED flashes 3x
slowly and 6x rapidly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Setting options:
p0 = Normal machine height (G
1xxx); p1 = XXL model (G 2xxx).
Model setting
1
Press the Delay Start
button 38x. The "Delay
Start" LED flashes 3x
slowly and 8x rapidly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. Individual setting
possibilities depend on model and
whether a circulation pump with
slide shutter (WAW), sensor
softener (SEH), and/or salt
container in door (SIT) are fitted.
Appropriate setting: p1 = G 1202
(w/out WAW, w/out SEH, w/out
SIT).
Country setting
1
Press the Delay Start
button 39x. The "Delay
Start" LED flashes 3x
slowly and 9x rapidly
intermittently. Press the
Start/Stop button as
appropriate to make the
desired setting.
The "Rinse" LED is off or flashes.
The display shows p and a digit
alternately. The following country
versions can be set: p1 = EUR
(Europe); p2 = AUS (Australia);
p3 = USA, p4 = JPN (Japan),
p5 = I/E (Italy/Spain), p6 = SER
(Southern Europe).
3
Table 080-8: Service Programming Mode, G 1202
1
If the electronic needs to be replaced during servicing, the following steps must be taken
during programming: In the first step, set the country specification and model, then switch
off the appliance. Repeat access and then set appliance width and height, and the
appropriate supply water hardness.
2
If the dishwasher is connected to an external ion exchanger water softener (i.e. that
needs to be regenerated with salt), the water hardness delivered by the system must be
set. If this value is unknown, set to 8°d (8.6 grains per gallon).
3
The SER country specification includes the following countries: Portugal, France, the
Netherlands, Belgium and Great Britain.
Save and quit:
Switch off the appliance.

Table of Contents

Other manuals for Miele Inspira G 2180

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele Inspira G 2180 and is the answer not in the manual?

Miele Inspira G 2180 Specifications

General IconGeneral
BrandMiele
ModelInspira G 2180
CategoryDishwasher
LanguageEnglish

Related product manuals