G 1xxx/G 2xxx
Cause (ID nos. -1404, -1465 only):
Faulty position monitoring of the comfort door closing aid (CTSH).
For a switched-off appliance, the door-closing function is in operation.
Under adverse conditions, the locking system can stop in a faulty position.
The control electronic recognizes this as a “zero position” and interprets it
incorrectly. After the first (or a later) water intake, the fault loop occurs. The
machine drains for 4 minutes and, after the water intake, synchronizes the
heating relay. Spray arm heating occurs up to activation of the boiling protection.
Remedy:
1. Replace the heater relay.
2. Install an electronic (SLT) with ID number -1505 or higher.
3.23 Fault Code F32: Door Lock Does Not Close
Symptom:
The drain pump is operated, and any running program is interrupted.
See Table 080-3 for model-specific fault indications.
Cause:
The given time for retraction of the adjustable door lock latch from position 3
to 2, or 2 to 1 (see Section 020-2.5) is not sufficient.
Remedy:
1. Check if there is supply voltage.
2. Replace the comfort door closing aid; see Section 020-4.9.
Cause:
Given time period for new positioning exceeded.
Remedy:
1. Check if there is supply voltage.
2. Replace the comfort door closing aid; see Section 020-4.9.
3.24 Fault Code F33: Door Lock Does Not Open
Symptom:
The drain pump is operated, and any running program is interrupted.
See Table 080-3 for model-specific fault indications.
Cause:
The given time for extension of the adjustable door lock latch from position 1
to 2, or 2 to 3 (see Section 020-2.5) is not sufficient.
Remedy:
1. Check if there is supply voltage.
2. Replace the comfort door closing aid; see Section 020-4.9.
Cause:
Given time period for new positioning exceeded.
Remedy:
1. Check if there is supply voltage.
2. Replace the comfort door closing aid; see Section 020-4.9.

Table of Contents

Other manuals for Miele Inspira G 2180

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele Inspira G 2180 and is the answer not in the manual?

Miele Inspira G 2180 Specifications

General IconGeneral
BrandMiele
ModelInspira G 2180
CategoryDishwasher
LanguageEnglish

Related product manuals