(b) List of setting functions
Setting and display items Detailed contents
1. Remote control network
1
2
Multiple heat pump water heater control
Max. 16 sets of heat pump water heaters in one Superlink network can be
connected to one remote control and controlled by it.
Heat pump water heaters shall be set addresses.
Main or Sub remote control setting
2 remote controls can be connected to one remote control network.
One of them is set " Main" and the other one is set " Sub" .
2. TOP screen, switch operation
1
2
3
4
5
6
7
Menu 
Hot water temperature Set the temperature to top up and the temperature to keep warm
Hot water amount Set the hot water amount. (More/Usual/Less)
Usage of hot water amount Display the usage of hot water amount today and yesterday
Run/P ause switch Start operation or pause operation
Schedule setting switch Set schedule. See item 3 for details
 Set hot water amount 100% and start operation to top up
3. Schedule settings
1
2
3
4
Setting of weekly operation pattern Set the operation pattern for one week.
Set target hot water amount and time



Setting of day off If setting off day, the operation of heat pump water heater to top up becomes
invalid.



Setting of peak cut Reduce the power consumption by limiting the max. capacity.
Set the start/end time of peek-cut and the peak-cut %.






Checking of operation pattern It is available to check the current operation pattern
4. Initial settings
1
2
3
4
5
Clock setting Set or correct the current date and time

for back-up.
Date and time display On/Off, 12H/24H or display position of AM/P M can be set
Contrast The contrast of LCD can be adjusted.
Backlight On/Off and lighting time of backlight can be set.
Control sound On/Off of beep sound at touch panel operation an be set
5. Administrator settings Adminstrator password is required
1
2
E nable/Disable setting 

[Change set temp], [Change amount of top up]
N ight tariff setting In order to calculate the power consumption in day/night time, the time zone
applied night tariff can be set.
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries ESA30E-25 and is the answer not in the manual?

Mitsubishi Heavy Industries ESA30E-25 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelESA30E-25
CategoryHeat Pump
LanguageEnglish

Related product manuals