66
-
'15 • HM-T-246
LapesaGrupoE mpresarial, S.L
Model name GX -1000-RB
 C
Standing loss 125 W
Storage volume 1000 L
a) Average condition
*1...COP
DHW
/ 2.5*2...(Total enrgy consumption)*0.6*366
b) Colder condition
*1...COP
DHW
/ 2.5*2...(Total enrgy consumption)*0.6*366
c) Warmer condition
*1...COP
DHW
/ 2.5*2...(Total enrgy consumption)*0.6*366
E nergy consumption
kWh
Tapping heat
kWh
Tapping cycle 0.719 24.848
Standby power input 0.517 -
Re-heating period 7.206 -
①~③

Total energy consumption
8.442 24.848
P erformance
COP
DHW
2.94
Wh
(
*
1)
117.7%
Annual energy consumption
(
*
2)
1854kWh
E nergy consumption
kWh
Tapping heat
kWh
Tapping cycle 3.640 24.884
Standby power input 2.449 -
Re-heating period 8.009 -
Defrosting period1 1.229 -
①~③

Total energy consumption
8.442 24.884
P erformance
COP
DHW
1.62
Wh
(
*
1)
64.9%
Annual energy consumption
(
*
2)
3366.0%
E nergy consumption
kWh
Tapping heat
kWh
Tapping cycle 0.751 24.994
Standby power input 0.514 -
Re-heating period 6.177 -
①~③

Total energy consumption
7.442 24.994
P erformance
COP
DHW
3.34
Wh
(
*
1)
133.6%
Annual energy consumption
(
*
2)
1683kWh
3) Technical data of storage cylinder
4) Result of the measurement
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries ESA30E-25 and is the answer not in the manual?

Mitsubishi Heavy Industries ESA30E-25 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelESA30E-25
CategoryHeat Pump
LanguageEnglish

Related product manuals