5
-
'15 • HM-T-246
Table1. OK or N O for mounting parts in the specification category A to the specification category B
○: for OK to mount
× : for N O
Specification category B
Table2. OK or N O for mounting parts in the specification category A to the specification category A
○: for OK to mount
× : for N O
It has brackets to hook the front panel, but it can be
mounted. It is, however, limited to the front side only.
Front panel
R:P CB122A122
×
Front panel in Category B has hooks so that
it cannot be mounted on conventional models.
L:P CB122A122A ×
P CB131A042A ○
Frame P CB115A116B ○
P arts in category B
Fan guard P CB131A041
○
Appearance is changed. (Mesh size of fan guard
in Category B is smaller than that in Category A.)
Side panel
R:P CB123A090N
○
L:P CB123A090P ○
Fin guard
P CB131A042
○
Appearance is changed. (Fin guard in Category
B has the base section shorter by 5 mm after
the structural change to hook the front panel.)
Frame P CB115A116 ×
Frame in Category A has not brackets to hook
the front panel so that it cannot be mounted.
Item P art N o.
Application to current model
(Specification category A)
Remark
Fin guard
P CB131A030
×
Base section of fin guard in Category A is
5 mm longer. This makes difficult to remove
the front panel so that it cannot be mounted.
P CB131A030A
Front panel
R:P CB122A091
○
L:P CB122A091C ○
Item P art N o. Remark
P arts in category A
Fan guard P CB131A025A
○
Appearance is changed. (Mesh size of fan guard in
Category A is larger than that in Category B.)
Side panel
R: P CB123A090D
×
Side panel in Category B has hooks to
hold the front panel. Conventional parts
without the hooks cannot be mounted.
L: P CB123A090F
×
×
www.ampair.co.uk | sales@ampair.co.uk