NISSEI CORPORATION E6581815
C-13
3
3.4 Setting the electronic thermal
 : Motor electronic-thermal protection level 1
: Motor 150% overload detection time
: Electronic-thermal memory
Function
This parameter allows selection of the appropriate electronic thermal protection characteristics according
to the particular rating and characteristics of the motor.
[Parameter setting]
Title Function Adjustment range Default setting

Motor electronic-thermal
protection level 1
10 – 100 (%) / (A) *1
0.1kW model : 64
0.2kW model : 61
0.4kW model : 73
0.75kW model : 80
1.5kW model : 82
2.2kW model : 82
f607
Motor 150% overload
detection time
10 – 2400 (s) 60
 Electronic-thermal memory
0: Disabled
1: Enabled *2
0
*1: The inverter's rated current is 100%. When  (current and voltage unit selection) = 1 (A (amps)/V
(volts)) is selected, it can be set at A (amps).
*2: The thermal status (overload totaling level) of the inverter or motor is saved when the power is turned off,
and is calculated when the power is turned on from the off status.