NISSEI CORPORATION E6581815
F-4
6
6.2 Input signal selection
6.2.1 Priority selection (Both F and R are ON)
 : Priority selection (Both F and R are ON)
Function
This parameter allows you to select the direction in which the motor runs when a forward run (F)
command and a reverse run (R) command are entered simultaneously.
1) Reverse
2) Slowdown stop
[Parameter setting]
Title Function Adjustment range Default setting

Priority selection (Both F and R are
ON)
0: Reverse
1: Slowdown stop
1
Output frequency attainment signal
Forward run command
 
ON
OFF
 

ON
OFF
0
Output frequency [Hz]
Time [s]