4.3
Functions useful in searching for a parameter or changing a parameter
setting
This section explains functions useful in searching for a parameter or changing a parameter setting. To use these
functions, a parameter needs to be selected or set in advance.
Changed parameters history search (History function) 
This function automatically searches for the last five parameters whose settings have been changed. To use this
function, select the  parameter. (Any changes are displayed regardless of whether or not they are the same as
standard defaults)
Refer to section 5.1 for details.
Set parameters by purpose (Guidance function) 
Only parameters required for a special purpose can be called up and set.
To use this function, select parameter .
Refer to section 5.2 for details.
Reset parameters to default settings 
Use the  parameter to reset all parameters back to their default settings.
To use this function, set parameter =.
Note) When once the customer settings saved with =, it cannot return to the default settings.
Refer to section 4.3.2 for details.
Call saved customer settings 
Customer settings can be batch-saved and batch-called.
These settings can be used as customer-exclusive default settings.
To use this function, set parameter = or .
Refer to section 4.3.2 for details.