6
Safety Precautions
Do not connect resistors to the terminals (+1, P/+2, N/-) directly.
Doing so might result in a small-scale fire, heat generation or damage to the unit.
Install a stop motion device to ensure safety. Not doing so might result in a minor injury. (A holding
brake is not a stop motion device designed to ensure safety.)
Be sure to use a specified type of braking resistor/regenerative braking unit. In case of a braking
resistor, install a thermal relay that monitors the temperature of the resistor. Not doing so might
result in a moderate burn due to the heat generated in the braking resistor/regenerative braking
unit. Configure a sequence that enables the Inverter power to turn off when unusual overheating is
detected in the braking resistor/regenerative braking unit.
The Inverter has high voltage parts inside which, if short-circuited, might cause damage to itself or
other property. Place covers on the openings or take other precautions to make sure that no metal
objects such as cutting bits or lead wire scraps go inside when installing and wiring.
Do not touch the Inverter fins, braking resistors and the motor, which become too hot during the
power supply and for some time after the power shutoff. Doing so may result in a burn.
Take safety precautions such as setting up a molded-case circuit breaker (MCCB) that matches
the Inverter capacity on the power supply side. Not doing so might result in damage to property due
to the short circuit of the load.
Do not dismantle, repair or modify the product.
Doing so may result in an injury.
CAUTION

Table of Contents

Other manuals for Omron 3G3JX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3JX and is the answer not in the manual?

Omron 3G3JX Specifications

General IconGeneral
Model3G3JX
CategoryInverter
Control MethodV/f control
Input Frequency50/60 Hz
Communication InterfaceRS-485 (optional)
Operating Temperature-10 to 50°C
Humidity20 to 90% RH (non-condensing)
Enclosure RatingIP20
Input Voltage200 to 240 V AC
Output VoltageThree-phase 200 to 240 V AC
Output Frequency400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Braking UnitBuilt-in
Power Range0.1 to 15 kW
Cooling MethodFan-cooled
Storage Temperature-20°C to +65°C
AltitudeUp to 1000 m