4-6
4-2 Function Mode
4
Functions
•The set time here indicates the acceleration/deceleration time between 0 Hz and the maximum
frequency.
Even if a short acceleration/deceleration time is set, the actual time cannot be shorter than the
minimum acceleration/deceleration time that is determined by the mechanical inertia moment and
the motor torque. If you set a time shorter than the minimum time, an overcurrent/overvoltage trip
may occur.
For short-time deceleration, use the regenerative braking unit (optional).
Digital Operator Rotation Direction Selection
Select the direction of motor rotation applied to the RUN command via the Digital Operator.
This is disabled at terminals.
Output frequency
Max. frequency
A004/A204
Output frequency set valu
e
Actual
acceleration
time
Actual
deceleration
time
F002/F202
F003/F203
LS
MML
S
TT
NJJ
T
9.55
Acceleration Time TS
=
(
+
)
×
×
()
–
Deceleration Time T
B
LB
MML
B
TT
NJJ
T
9.55
=
(
+
)
×
×
()
+
J
L :Inertia moment of the load converted to the motor shaft [kg·m
2
]
J
M :Inertia moment of the motor [kg·m
2
]
N
M :Motor rotation speed [r/min]
T
S :Max. acceleration torque with the Inverter driving [N·m]
T
B :Max. deceleration torque with the Inverter driving [N·m]
T
L :Required driving torque [N·m]
Parameter No. Function name Data Default setting Unit
F004
Operator rotation
direction selection
00: Forward
01: Reverse
00 ⎯

Table of Contents

Other manuals for Omron 3G3JX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3JX and is the answer not in the manual?

Omron 3G3JX Specifications

General IconGeneral
BrandOmron
Model3G3JX
CategoryInverter
LanguageEnglish

Related product manuals