EasyManuals Logo
Home>Omron>DC Drives>3G3RX

Omron 3G3RX User Manual

Omron 3G3RX
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
4-60
4-2 Function Mode
4
Functions
Dual Rating Selection
•Ratings of the inverter are switched to Heavy Duty (CT) and Normal Duty (VT) and it enables it.
The ratings current value changes by switching Heavy Duty (CT) and Normal Duty (VT).
•The method of switching a Heavy Duty and a Normal Duty is done by Heavy Duty/Normal Duty
selection (b049) in the operator.
•In the Normal Duty (VT), there is the item which is not displayed in the parameter of the operator.
Parameter No. Function name Data Default setting Unit
b049 Dual Rate Selection
00: CT (Constant torque)
01: VT (Variable torque)
00 
Parameter No. Function name Function code Function name
d008 Real frequency monitor P024 Position bias amount
d009 Torque reference monitor P025
Secondary resistance compensation enable/
disable selection
d010 Torque bias monitor P026 Overspeed error detection level
d029 Positioning command monitor P027 Speed deviation error detection level
d030 Current position monitor P028 Motor gear ratio numerator
b120 Brake control enable P029 Motor gear ratio denominator
b121 Brake wait time for release P032 Orientation stop position input type
b122 Brake wait time for acceleration P033 Torque reference input selection
b123 Brake wait time fot stopping P034 Torque reference setting
b124 Brake wait time for confirmation P035 Polarity selection at torque reference via O2
b125 Brake release frequency P036 Torque bias mode
b126 Brake release current P037 Torque bias value
b127 Brake input frequency P038 Torque bias polarity selection
H060 Limit at 0 Hz P039 Speed limit value in torque control (forward)
H260 *2nd limit at 0 Hz P040 Speed limit value in torque control (reverse)
H061
Boost amount at SLV startup,
0 Hz
P060 Multi-step position command 0
H261
*2nd boost amount at SLV
startup, 0 Hz
P061 Multi-step position command 1
P011 Encoder pulses P062 Multi-step position command 2
P012 V2 control mode selection P063 Multi-step position command 3
P013 Pulse train mode selection P064 Multi-step position command 4
P014 Orientation stop position P065 Multi-step position command 5
P015 Orientation speed setting P066 Multi-step position command 6
P016 Orientation direction setting P067 Multi-step position command 7
P017 Position ready range setting P068 Zero return mode
P018 Position ready delay time setting P069 Zero return direction selection
P019
Electronic gear setting position
selection
P070 Low-speed return frequency
P020 Electronic gear ratio numerator P071 High-speed zero return frequency
P021 Electronic gear ratio denominator P072 Position range specification (forward)
P022 Position control feedforward gain P073 Position range specification (reverse)
P023 Position loop gain P074 Teaching selection

Table of Contents

Other manuals for Omron 3G3RX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3RX and is the answer not in the manual?

Omron 3G3RX Specifications

General IconGeneral
BrandOmron
Model3G3RX
CategoryDC Drives
LanguageEnglish

Related product manuals