EasyManuals Logo
Home>Omron>DC Drives>3G3RX

Omron 3G3RX User Manual

Omron 3G3RX
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
3-31
3-9 Parameter List
3
Operation
External frequency adjustment
A101 OI start frequency
0.00 to 400.00
0.00 No Hz
4-14
A102 OI end frequency 0.00 No Hz
A103 OI start ratio 0 to OI end ratio 20 No %
A104 OI end ratio OI start ratio to 100 100 No %
A105 OI start selection
00: Start FQ (Use OI start frequency [A101])
01: 0 Hz
00 No 
A111 O2 start frequency
-400.00 to 400.00
0.00 No Hz
4-15
A112 O2 end frequency 0.00 No Hz
External frequency adjustment
A113 O2 start ratio -100 to O2 end ratio -100 No %
A114 O2 end ratio O2 start ratio to 100 100 No %
Accel/Decel
A131
Acceleration curve
parameter
01 (small curve) to 10 (large curve)
02 No 
4-38
A132
Deceleration curve
parameter
02 No 
Operation frequency
A141
Operation frequency
input A setting
00: Operator (Digital Operator (F001))
01: VR (Digital Operator (FREQ adjuster))
(Enabled when 3G3AX-OP01 is used.)
02: O (Input O)
03: OI (Input OI)
04: Modbus (RS485 communication)
05: Option 1
06: Option 2
07: Pulse (Pulse train frequency)
02 No 
4-41
A142
Operation frequency
input B setting
03 No 
A143 Operator selection
00: ADD (Addition (A + B))
01: SUB (Subtraction (A - B))
02: MUL (Multiplication (A × B))
00 No 
A145
Frequency addition
amount
0.00 to 99.99
100.0 to 400.0
0.00 No Hz
4-41
A146
Frequency addition
direction
00: ADD (Add A145 value to output
frequency)
01: SUB (Subtract A145 value from output
frequency)
00 No 
Acceleration/Deceleration
A150
EL-S-curve ratio 1
during acceleration
0 to 50 10 No %
4-39
A151
EL-S-curve ratio 2
during acceleration
0 to 50 10 No %
A152
EL-S-curve ratio 1
during deceleration
0 to 50 10 No %
A153
EL-S-curve ratio 2
during deceleration
0 to 50 10 No %
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.

Table of Contents