10–Converged Network Adapter Interactive Commands
iSCSI Port Diagnostics
SN0054667-00 C 10-125
iSCSI Port Diagnostics
4. Adapter Diagnostics1. Converged Network Adapter11. iSCSI Port Diagnostics
From the Converged Network Adapter (CNA) Diagnostics menu, select the iSCSI
Port Diagnostics option. From the port menu, select a port to open the iSCSI
Port Diagnostics menu with options to ping the target device and test the read
write buffer. For example:
Converged Network Adapter (CNA) Diagnostics
CNA Model QLE8242 SN: AFE1028C03899
1. Port 2 [Protocol(s): NIC iSCSI FCoE]
MAC Address: 00:0E:1E:04:95:EC
WWPN: 21-00-00-0E-1E-04-95-EF
Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed
2. Port 1 [Protocol(s): NIC iSCSI FCoE]
MAC Address: 00:0E:1E:04:95:E8
WWPN: 21-00-00-0E-1E-04-95-EB
Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online
(p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
Please Enter Selection: 2
iSCSI Port Diagnostics
=======================================================
CNA : 0 Port: 1
SN : AFE1028C03899
CNA Model : QLE8242
iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4
FW Version : 4.7.31
iSCSI MacAddr : 00:0E:1E:04:95:EA
IPv4 Address : 192.168.1.45
=======================================================
1: Ping Target
2: Perform Read/Write Buffer Test