Issue 10/06 3 Functions
MICROMASTER 440 Operating Instructions
6SE6400-5AW00-0BP0
47
3 Functions
This Section includes the following:
¾ Explanation of the MICROMASTER 440 parameters
¾ An overview of the parameter structure of MICROMASTER 440
¾ A description of the display and operator control elements and communications
¾ A block diagram of MICROMASTER 440
¾ An overview of the various ways of commissioning the MICROMASTER 440
¾ A description of the inputs and outputs
¾ Possibilities of controlling (open-loop and closed-loop) the MICROMASTER 440
¾ A description of the various functions of the MICROMASTER 440 and their
implementation
¾ Explanation and information on the protective functions
3.1
Parameters ............................................................................................................. 51
3.1.1 Setting / monitoring parameters and parameter attributes ..................................... 51
3.1.2 Interconnecting signals (BICO technology) ............................................................ 57
3.1.2.1 Selecting the command source P0700 / selecting the setpoint source P1000....... 57
3.1.2.2 Selection of command/frequency setpoint P0719 .................................................. 59
3.1.2.3 BICO technology..................................................................................................... 60
3.1.3 Data sets................................................................................................................. 63
3.1.4 Reference quantities............................................................................................... 68
3.2 Operator panels for MICROMASTER..................................................................... 70
3.2.1 Description of the BOP (Basic Operator Panel) ..................................................... 70
3.2.2 Description of the AOP (Advanced Operator Panel) .............................................. 71
3.2.3 Keys and their functions on the operator panel (BOP / AOP) ................................ 72
3.2.4 Changing parameters using the operator panel ..................................................... 73
3.3 Block diagram ......................................................................................................... 74
3.4 Factory setting ........................................................................................................ 75
3.5 Commissioning ....................................................................................................... 77
3.5.1 50/60 Hz setting...................................................................................................... 79
3.5.2 Motor circuit ............................................................................................................ 80
3.5.3 Quick commissioning.............................................................................................. 83
3.5.4 Calculating the motor / control data........................................................................ 88
3.5.5 Motor data identification.......................................................................................... 91
3.5.6 Magnetizing current ................................................................................................ 95
3.5.7 Commissioning the application............................................................................... 97
3.5.7.1 Serial Interface (USS)............................................................................................. 97
3.5.7.2 Selection of command source ................................................................................ 98
3.5.7.3 Digital input (DIN).................................................................................................... 98
3.5.7.4 Digital output (DOUT) ............................................................................................. 99
3.5.7.5 Selection of frequency setpoint............................................................................. 100
3.5.7.6 Analog input (ADC)............................................................................................... 101

Table of Contents

Other manuals for Siemens MICROMASTER 440

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MICROMASTER 440 and is the answer not in the manual?

Siemens MICROMASTER 440 Specifications

General IconGeneral
Power Range0.12 kW to 250 kW
Output Voltage0 V to Input Voltage
Output Frequency0 Hz to 650 Hz
Control ModesVector control
Overload Capability150% for 60 seconds
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature, Short Circuit, Ground Fault
Communication InterfacesPROFIBUS, DeviceNet, CANopen, Modbus RTU
Enclosure RatingIP20
Ambient Temperature-10°C to +50°C
Input Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)