Communic
ation
2.1
PROF
IBUS co
mmunica
tion
SIMOCODE
pro
-
Communication
Functi
on Manual
,
11/2018
,
A5E40508495002A/RS
-
AC/003
15
2.1.2
Data trans
fer
Options for
data transfer
The follow
ing fig
ure shows
the d
ata trans
fer opti
ons:
Figure
2-1
Options for data tran
sfer
14
16
Table of Contents
Default Chapter
3
Table of Contents
3
1 Introduction
7
Important Notes
7
Security Information
10
Current Information about Operational Safety
11
2 Communication
13
PROFIBUS Communication
13
Definitions
13
Data Transfer
15
Fail-Safe Data Transfer Via PROFIBUS / Profisafe
16
Telegram Description and Data Access
17
Cyclic Data
17
Diagnostics Data and Alarms
18
Structure of the Slave Diagnostics
19
Integration of SIMOCODE Pro in DP Master Systems
28
Slave Operating Modes
28
Preparing the Data Transfer
28
Integration of SIMOCODE Pro as a DPV1 Slave Via GSD in the Configuring Software
29
Integration of SIMOCODE Pro as a SIMATIC PDM Object (DPV1 Slave Via GSD) in STEP7 HW Config
31
Integration of SIMOCODE Pro as an S7 Slave Via OM SIMOCODE Pro
32
Compatibility of SIMOCODE Pro S and SIMOCODE Pro V
33
Evaluating Diagnostics Data
34
SIMOCODE Pro Integrated with GSD
34
Integration of SIMOCODE Pro in SIMATIC S7 with OM SIMOCODE es
36
Data Records
37
Parameterization Via PROFIBUS
38
SIMOCODE es Premium
38
Simatic Pdm
39
Parameter Data During Startup
40
Timestamping/Time Synchronization
40
PROFINET Communication
41
Definitions
41
Data Security in Automation
43
Data Transfer
45
Communication Via PROFINET IO
46
Integration of SIMOCODE Pro into the Automation System (PLC)
48
Integration of SIMOCODE Pro V PN Via GSD
51
Integration of SIMOCODE Pro V PN in SIMATIC STEP 7 V5 Via OM SIMOCODE Pro
52
Configuring SIMOCODE Pro V PN Ports
53
Configuration of Further Properties of SIMOCODE Pro V PN as an IO Device
54
Identification Data for PROFINET IO
57
Shared Device
58
Media Redundancy
58
System Redundancy
59
Diagnostics
65
Data Records
77
Profienergy
78
Further Communication Functions Via Ethernet
81
Modbus Communication
95
Modbus RTU Communication
95
Modbus RTU - General
95
Supported Data Transfer Rates for RTU
95
Assignment of SIMOCODE Data to Modbus Addresses with Modbus RTU
95
Modbus RTU Data Transfer
96
Modbus RTU Telegram Format
97
Modbus RTU Function Codes
98
Modbus RTU Error Codes
109
Ethernet/Ip Communication
110
Important Notes
110
Definitions
110
Data Security in Automation
112
Data Transmission
112
Electronic Data Sheet (EDS) File
113
Setting up the IP Address
114
Address Collision Detection (ACD)
115
Parameterizing the Device
116
Integrating SIMOCODE Pro into the Automation System (PLC)
117
Integration and Commissioning in Rockwell Studio 5000
118
Ethernet/Ip Device Level Ring Functionality
119
Ethernet/Ip System Redundancy
119
Web Diagnostics
120
Time-Of-Day Synchronization by the NTP Procedure
122
Simple Network Management Protocol (SNMP)
123
3 Tables, Data Records
125
Tables General
125
Active Control Stations, Contactor Controls, Lamp Controls and Status Information for the Control Functions
125
Assignment of Cyclic Receive and Send Data for Predefined Control Functions
128
Overload Relay
128
Direct Starter
129
Reversing Starter
130
Molded-Case Circuit Breaker (MCCB)
131
Star-Delta Starter
132
Star-Delta Reversing Starter
133
Dahlander Starter
134
Dahlander Reversing Starter
135
Pole-Changing Starter
136
Pole-Changing Reversing Starter
137
Solenoid Valve
138
Positioner
139
Soft Starter
140
Soft Starter with Reversing Contactor
141
Tables, PROFIBUS Data Records
142
PROFIBUS Tables
142
Abbreviations and Specifications
142
Socket Assignment Table - Digital
143
Socket Assignment Table - Analog
150
Detailed Messages of the Slave Diagnostics
153
PROFIBUS Data Records
157
PROFIBUS Data Records - General
157
Data Record 0/1 - S7 System Diagnostics
160
Data Record 63 - Analog Value Recording
162
Data Record 67 - Process Image Output
162
Data Record 69 - Process Image Input
163
Data Record 72 - Error Buffer
164
Data Record 73 - Event Memory
164
Data Record 92 - Device Diagnostics
165
Data Record 94 - Measured Values
172
Data Record 95 - Service Data/Statistical Data
174
Data Record 130 - Basic Device Parameters 1
175
Data Record 131 - Basic Device Parameters 2 (Plug Binary)
181
Data Record 132 - Extended Device Parameters 1
185
Data Record 133 - Extended Device Parameters 2 (Plug Binary)
193
Data Record 134 - Extended Device Parameters 2
196
Data Record 135 - Extended Device Parameters 2
196
Data Record 139 - Marking
197
Data Record 160 - Communication Parameters
198
Data Record 165 - Identification
198
Data Record 202 - Acyclic Receive
199
Data Record 203 - Acyclic Send
200
Data Record 224 - Password Protection
201
Tables, PROFINET Data Records
202
PROFINET Tables
202
OPC UA Variables
202
Abbreviations and Specifications
211
Socket Assignment Table - Digital
212
Socket Assignment Table - Analog
219
PROFINET Data Records
223
PROFINET Data Records - General
223
Data Record 63 - Analog Value Recording
226
Data Record 67 - Process Image Output
226
Data Record 69 - Process Image Input
227
Data Record 72 - Error Buffer
228
Data Record 73 - Event Memory
228
Data Record 92 - Device Diagnostics
229
Data Record 94 - Measured Values
238
Data Record 95 - Service Data/Statistical Data
240
Data Record 130 - Basic Device Parameters 1
242
Data Record 131 - Basic Device Parameters 2 (Plug Binary)
248
Data Record 132 - Extended Device Parameters 1
252
Data Record 133 - Extended Device Parameters 2 (Plug Binary)
260
Data Record 134 - Extended Device Parameters 2
263
Data Record 135 - Extended Device Parameters 2
269
Data Record 139 - Marking
272
Data Record 140 - Marking 2
273
Data Record 165 - Identification
274
Data Record 224 - Password Protection
274
Modbus Data Tables
275
General Information
275
Memory Image
275
Byte Arrangement
276
Specifications
276
Modbus RTU Data Tables
277
Process Image Output - Command Data
277
Process Image Input - Monitoring Data
278
Measured Values
279
Display and Statistical Data
281
Device Diagnostics
282
Error Memory
289
Event Memory
290
Trace Data
291
I&M0 - Device Identification
292
I&M1 Data
292
I&M2 - Installation Date
293
I&M3 - Comment
293
Basic Device Parameter 1
294
Extended Device Parameters 1
301
Marking
312
Ethernet/Ip Data Tables
313
Supported Objects
313
Identity Object
314
Message Router Object
316
Assembly Object
316
Connection Manager Object
327
Device Diagnosis Object
328
Measurement Object
329
Statistical Data Object
331
Motor Parameter Object
333
TCP/IP Interface Object
335
Ethernet Link Object
336
List of Abbreviations
337
A.1 List of Abbreviations
337
Index
339
Other manuals for Siemens SIMOCODE pro
Programming And Operating Manual
286 pages
Operating Manual
278 pages
Manual
118 pages
System Manual
694 pages
Operating Instructions
4 pages
Original Operating Instructions
4 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Siemens SIMOCODE pro and is the answer not in the manual?
Ask a question
Siemens SIMOCODE pro Specifications
General
Brand
Siemens
Model
SIMOCODE pro
Category
Control Unit
Language
English
Related product manuals
Siemens SIMOCODE pro V PB
408 pages
Siemens SIMOCODE pro PCS 7
286 pages
Siemens SIMOCODE pro C
408 pages
Siemens SIMOCODE pro S
408 pages
Siemens SIMOCODE pro V MR
408 pages
Siemens SIMOCODE pro V EIP
408 pages
Siemens SIMOTION
184 pages
Siemens SIMOTION D445
150 pages
Siemens SIMOTION CX32
130 pages
Siemens SIMOTION D435-2
146 pages
Siemens SIMOTION D425-2
146 pages
Siemens SIMOTION D4x5-2
432 pages