Technical data
5
5.1 Shipping and storage conditions
The following conditions apply to modules that are shipped and stored in the original
packaging.
Table 5-1 Shipping and storage conditions
Type of condition Permissible range/class
Transport Long-term storage
Climate class 2K4 according to
EN 60721‑3‑2:1997
1K4 according to
EN 60721‑3‑1:1997
Vibration and shock stressing
(in transport packaging)
EN 60721‑3‑2:1997, class
2M3
EN 60721‑3‑1:1997, class
1M2
Permissible ambient temperature -40° C …+70° C -25° C …+55° C
Relative humidity 5 … 95% 10 … 100%
Height Max. 4000 m above sea level
Atmospheric pressure 620 hPa … 1060 hPa
The specied values apply to
a transportation altitude of
up to 4000 m.
620 hPa … 1060 hPa
The specied values apply to
a storage altitude of up to
4000 m.
Biological environmental conditions Class 2B1 according to EN
60721‑3‑2:1997
Class 1B1 according to EN
60721‑3‑1:1997
Chemically active environmental condi‐
tions
Class 2C2 according to EN
60721‑3‑2:1997
Class 1C2 according to EN
60721‑3‑1:1997
5.2 Ambient conditions
Conditions of use
SIMOTION D410-2 meets the conditions of use for Class 3C3 according to
DIN EN 60721‑3‑3:1995 (operating locations with high trac densities and in the immediate
vicinity of industrial equipment with chemical emissions).
Protect the device from environmental eects
SIMOTION D410-2 is designed for use in stationary, weather-protected locations.
Protect the device against the following environmental eects:
• Direct sunshine and heat sources
• Mechanical vibration and shock
• Dust
SIMOTION D410-2