5.3 System data, connection values, dimensions and weight
General technical data
The SIMOTION D410‑2 has an integrated fan.
Table 5-3 General technical data
Dimensions and weight
Dimensions W x H x D
D410-2 DP
D410-2 DP/PN
73 x 186.8 x 74.4 mm
73 x 190.7 x 74.4 mm
Weight
• Without packaging
• With packaging
• 830 g
• 1,000 g
Electrical connection values
Power supply 24 VDC (permissible range: 20.4 ... 28.8 V)
Ripple Max. 5% at 24 VDC
Non-periodic overvoltage Max. 35 VDC
(Condition: Max. 500 ms, 50 s recovery time, max.
10 results/h)
Current consumption, typically
1)
< 0.8 A
Starting current, typically
1)
3.0 A
Power loss, typically
1)
< 20 W
1)
With no load on I/Os and no 24 V supply via DRIVE‑CLiQ or PROFIBUS interface
Memory
Table 5-4 Technical data for memory
RAM (work memory) 120 MB (as of V5.3 SP1)
96 MB (V4.4 - V5.2 SP1)
48 MB (V4.3 SP1)
RAM disk (load memory) 60 MB (as of V5.3 SP1)
47 MB (V4.4 - V5.2 SP1)
31 MB (V4.3 SP1)
Retentive memory
(retain variables)
At least 108 KB
Persistent memory
(user data on CF card)
2 GB CF card: At least 1.5 GB
1 GB CF card: At least 300 MB
Work memory for Java applications 20 MB
Non-volatile data buering
buer time, min. Unlimited (maintenance-free backup)
Memory for system data
Diagnostic buer (non-volatile) 100 messages (SIMOTION)
100 messages (SINAMICS Integrated)
Technical data
5.3 System data, connection values, dimensions and weight
SIMOTION D410-2
84 Equipment Manual, 07/2021, A5E33446720B