10.2.2.3 Download from BOP-2 operator panel
Overview
You can transfer the converter settings that are backed up on the BOP-2 operator panel back into
the converter.
Requirement
The following preconditions apply:
• You know the password for the converter safety functions.
• The converter power supply has been switched on.
• The converter settings are not protected against copying.
Download with active know-how protection with copy protection (Pageî™ 401)
Function description
Procedure
1. Attach the Operator Panel to the converter.
2. Select the download from the operator panel to the converter.
2.2.
3. Start the download.
2.
4. Wait until the download is completed.
2.
5. After loading, check whether the converter outputs Alarm A01028.
2.2.
– Alarm A01028:
The loaded settings are not compatible with the converter.
Delete the alarm with p0971î™ =î™ 1.
Recommission the drive.
– No alarm A01028: Proceed with the next step.
Corrective maintenance
10.2î™ Downloading the converter settings
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 393

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G120C
CategoryInverter
LanguageEnglish

Related product manuals