11.Switch on the converter power supply again.
12.Perform a reduced acceptance test.
Reduced acceptance after component replacement and 󹪝rmware change (Page417)
You transferred the settings from the PC to the new converter.
10.2.3 Download with active know-how protection with copy protection
Overview
The know-how protection function prevents converter settings from being copied.
There are two options to avoid recommissioning after a converter has been replaced.
Requirement
The following preconditions apply:
The end user uses a SIEMENS memory card.
The machine manufacturer (OEM) has an identical machine.
Function description
Procedure 1: The machine manufacturer only knows the serial number of the new
converter
1. The end customer provides the machine manufacturer with the following information:
For which machine must the converter be replaced?
What is the serial number (r7758) of the new converter?
2. The machine manufacturer performs the following steps online on the prototype machine:
Deactivating know-how protection
Activating and deactivating know-how protection (Page181)
Enter the serial number of the new converter in p7759.
Enter the serial number of the inserted memory card as reference serial number in p7769.
Activate know-how protection with copy protection. "Copy RAM to ROM" must be
activated.
Write the con󹪝guration with p0971 = 1 to the memory card.
Send the memory card to the end customer.
3. The end user inserts the memory card.
Corrective maintenance
10.2Downloading the converter settings
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 401

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals