11.4 DR 3 Belt scale parameters
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa 107
11.4.23 Warm-up timer
Following switching-on of the electronic weighing system, this input indicates in the status
area that the time has not yet expired ("Warm-up time running").
11.4.24 Interface for the legal trade display
This parameter is not yet effective since the function is in preparation.
The parameter defines the interface via which the data is provided for a display with
verification capability:
0 - no display with verification capability
1 - HMI SecureDisplay via Ethernet
2 - HMI SecureDisplay via S7 CPU
11.4.25 Software version for HMI SecureDisplay with verification capability
This parameter is not yet effective since the function is in preparation.
The SecDisplay.exe program is used for representation of the display with verification
capability. The software version must be entered when commissioning a trade scale
requiring verification. The following notation is envisaged: VX.XX.XX, e.g. V1.05.02
11.4.26 Minimum display size in % of the HMI SecureDisplay with verification capability
This parameter is not yet effective since the function is in preparation.
The smallest display size which can still be easily read is defined for representation of the
display with verification capability.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WT241 and is the answer not in the manual?

Siemens SIWAREX WT241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WT241
CategoryAccessories
LanguageEnglish

Related product manuals