EasyManuals Logo
Home>Siemens>Accessories>SIWAREX WT241

Siemens SIWAREX WT241 User Manual

Siemens SIWAREX WT241
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
Communication
11.5 Calibration procedure
SIWAREX WT241
110 Manual, 05/2015, A5E36046748A
Step 3 (only for systems without speed sensor)
Following successful zero and span calibrations, you can additionally record and store a
speed correction with loaded belt during operation (commands "Start speed measurement
"belt loaded"" (72) and "Stop speed measurement "belt loaded"" (73)). A coarse load
characteristic of the drive can be recorded in this manner. Import using the command "Apply
speed parameters "belt loaded"" (86).
11.5.3 Specification of known speed parameters
Calibration of the speed as described above is always recommended. This guarantees
maximum accuracy for the speed calculation and thus maximum accuracy of the complete
system.
If it is not possible to calculate the speed or pulse constant, you can also enter the data
manually.
When using a speed sensor at DI.0, you must enter the following parameters manually:
DR3 → design speed = maximum speed of belt
DR3 → belt revolution pulses = total belt length x pulse constant of sensor
When operating without a sensor, you must enter the following parameters manually:
DR3 → design speed = maximum speed of belt
With an external speed input via DR19, you must enter the following parameters
manually:
DR3 → design speed = maximum speed of belt

Table of Contents