Scale parameters and functions of the belt scale
8.8 Menu 1.6 Recovery / reset
SIWAREX WT241
72 Manual, 05/2015, A5E36046748A
tion
1.5.9.2 Speed simulation
Belt speed simu-
lation value
Enter the belt speed value to be simulated.
Start speed simu-
lation
Start simulation
Stop speed simu-
lation
Stop simulation
8.8 Menu 1.6 Recovery / reset
1.6.1 Recovery point
Setting the recovery point in this menu creates an image of all settings of the weighing proces-
sor. Reloading is possible anytime and will overwrite the current settings.
Create recovery
point
Creates an image of all settings. Execution will not be acknowledged.
Load recovery
point
Loads the latest created image. Execution will not be acknowledged.
Load standard
scale parameter
Like "Load factory settings", but interface settings for Ethernet and Mod-
bus RTU are not reset to the factory setting.
Load factory set-
tings
The command resets the SIWAREX to the "ex works" status. During this
process:
- all parameters and saved data (including protocol memory and logbook)
as well as the restore point are loaded with the default values
- all message buffers (diagnostics buffer, trace memory, etc.) are reset
8.9 Menu 2.1 Messages
Opens the message log of the weighing electronic.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WT241 and is the answer not in the manual?

Siemens SIWAREX WT241 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WT241
CategoryAccessories
LanguageEnglish

Related product manuals