Removal and Installation Procedures
AFG3000 Series Arbitrary/Function Generators Service Manual 6-9
16 mm (5/8 inch) deep socket with wide center hole
7 mm (9/32 inch) socket
Torque wrench to 30 in-lb (3.3 N m)
Screwdriver with 1/4 inch flat blade
Phillips head screwdriver
Pliers (all-purpose and needle-nose)
Tweezers
Flip Feet
You will need needle-nose pliers to remove the flip feet.
Removal. To remove the flip feet, refer to Figure 6-2 and follow these steps:
1. Place the arbitrary/function generator top down on a soft surface such as an
anti-static mat.
2. Grip the flip foot with the pliers as close to the notches as possible and squeeze
gently on the foot.
3. Twist slightly to swing one hinge free of the slot.
Figure 6-2: Removing and installing the flip feet
Installation.To install the flip feet, refer to Figure 6-2 and follow these steps:
1. Place the arbitrary/function generator top down on a soft surface such as an
anti-static mat.
2. Hold the flip foot with the smooth side facing down.
3. Gently squeeze the foot so that the hinge on one side fits into the slot, and twist
slightly to snap into the slot on the other side.