0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
www.ti.com
118
SLUUBD3D–September 2015–Revised September 2018
Submit Documentation Feedback
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
17.2.47 ManufacturerAccess() 0x0061 Lifetime Data Block 2
This command returns the Lifetime data on ManufacturerBlockAccess() or ManufacturerData(). See
Lifetimes for details.
Status Condition Action
Activate 0x0061 to ManufacturerAccess()
Outputs lifetime data values of Min Cell Voltage on
ManufacturerBlockAccess() or ManufacturerData()
17.2.48 ManufacturerAccess() 0x0062 Lifetime Data Block 3
This command returns the Lifetime data on ManufacturerBlockAccess() or ManufacturerData(). See
Lifetimes for details.
Status Condition Action
Activate 0x0062 to ManufacturerAccess()
Outputs lifetime data values of Delta Voltage, Currents,
Power and Temperatures on ManufacturerBlockAccess()
or ManufacturerData()
17.2.49 ManufacturerAccess() 0x0063 Lifetime Data Block 4
This command returns the Lifetime data on ManufacturerBlockAccess() or ManufacturerData(). See
Lifetimes for details.
Status Condition Action
Activate 0x0063 to ManufacturerAccess()
Outputs lifetime data of the Power events and Cell
Balancing Times data on ManufacturerBlockAccess() or
ManufacturerData(). (OLD, SCD, OTC, OTD)
17.2.50 ManufacturerAccess() 0x0064 Lifetime Data Block 5
This command returns the Lifetime data on ManufacturerBlockAccess() or ManufacturerData(). See
Lifetimes for details.
Status Condition Action
Activate 0x0064 to ManufacturerAccess()
Outputs lifetime data of the Time values on
ManufacturerBlockAccess() or ManufacturerData()
17.2.51 ManufacturerAccess() 0x0065 Lifetime Data Block 6
This command returns the Lifetime data on ManufacturerBlockAccess() or ManufacturerData(). See
Lifetimes for details.
Status Condition Action
Activate 0x0065 to ManufacturerAccess()
Outputs lifetime data of the safety events data on
ManufacturerBlockAccess() or ManufacturerData() (COV,
CUV, OCD, OCC)
17.2.52 ManufacturerAccess() 0x0066 Lifetime Data Block 7
This command returns the Lifetime data on ManufacturerBlockAccess() or ManufacturerData(). See
Lifetimes for details.
Status Condition Action
Activate 0x0066 to ManufacturerAccess()
Outputs lifetime data of the charger termination and FC
update events data on ManufacturerBlockAccess() or
ManufacturerData(). (OLD, SCD, OTC, OTD)

Table of Contents

Other manuals for Texas Instruments bq78350-R1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments bq78350-R1 and is the answer not in the manual?

Texas Instruments bq78350-R1 Specifications

General IconGeneral
BrandTexas Instruments
Modelbq78350-R1
CategoryController
LanguageEnglish

Related product manuals