Power Modes
Chapter 8
SLUUBD3D–September 2015–Revised September 2018
Power Modes
8.1 Introduction
To enhance battery life, the bq78350-R1 supports several power modes to minimize power consumption
during operation.
8.2 NORMAL Mode
In NORMAL mode, the device takes voltage, current, and temperature readings every 250 ms, performs
protection and gauging calculations, updates SBS data, and makes status readings at 1-s intervals.
Between these periods of activity, the device is in a reduced power state.
8.3 SLEEP Mode
8.3.1 Device Sleep
When the sleep conditions are met and the device is in REST (RELAX) mode, the device goes into
SLEEP mode with periodic wake-ups to reduce power consumption. The device returns to NORMAL mode
if any exit sleep condition is met.
(1)
DA Config[SLEEP] and SMBus low are not checked if the ManufacturerAccess() SLEEP mode command is used to enter
SLEEP mode.
(2)
A wake on an SMBus command is only possible when the gas gauge is put to sleep using the ManufacturerAccess() SLEEP
mode command. Otherwise, the gas gauge wakes on an SMBus connection (clock or data high).
Status Condition Action
Activate
SMBus low for BusTimeout
(1)
AND
DA Config[SLEEP] = 1
(1)
AND
|Current()| ≤ Sleep Current AND
Voltage Time > 0 AND
OperationStatus()[SDM] = 0 AND
No PFAlert() bits set AND
No PFStatus() bits set AND
No SafetyAlert() bits set AND
No [AOLD], [AOLDL], [ASCD], [ASCDL] set in
SafetyStatus()
Turn off CHG FET and PCHG FET if FET
Options[SLEEPCHG] = 0
Device goes to sleep.
Device wakes up every Sleep:Voltage Time period to
measure voltage and temperature.
Device wakes up every Sleep:Current Time period to
measure current.
Exit
SMBus connected
(1)
OR
SMBus command received
(2)
OR
DA Config[SLEEP] = 1
(1)
OR
|Current()| > Sleep Current OR
Voltage Time = 0 OR
OperationStatus()[SDM] = 1 OR
PFAlert() bits set OR
PFStatus() bits set OR
SafetyAlert() bits set OR
[AOLD], [AOLDL], [ASCD], [ASCDL] set in
SafetyStatus()
Return to NORMAL mode
The configuration options for SLEEP are in the following data flash.
Class Subclass Name Type Min Max Default Unit Description
Power Sleep Sleep Current I2 0 32767 10 mA |Current()| threshold to enter SLEEP mode
Power Sleep Bus Timeout U1 0 255 5 s SMBus low time to enter SLEEP mode
Power Sleep Voltage Time U1 0 255 5 s Voltage sampling period in SLEEP mode
Power Sleep Current Time U1 0 255 20 s Current sampling period in SLEEP mode

Table of Contents

Other manuals for Texas Instruments bq78350-R1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments bq78350-R1 and is the answer not in the manual?

Texas Instruments bq78350-R1 Specifications

General IconGeneral
BrandTexas Instruments
Modelbq78350-R1
CategoryController
LanguageEnglish

Related product manuals