78 RT-SVP04F-EN
System Programming SETUP
Assign Diagnostic to Alarm Output? Used With: All units with GBAS 0-
10VDC installed. (if ENTER pressed
above)
Possible values: YES/NO
GBAS 0-10VDC Module Comm Failure YES
1. Press the + or - key until the proper value is displayed.
2. Press the ENTER key to confirm this choice.
3. Press the NEXT key to advance the cursor.
4. Repeat steps 1 and 2 for the next value.
5. Press the NEXT key until the following screen is displayed
(if applicable).
Assignment Submenu - BAS/Network Alarms Used With: All units. (if "Any Active
Diagnostic" NO is selected above)
Press ENTER to Review or Adjust
1. Pressing the NEXT key will bypass this section.
Assign Diagnostic to Alarm Output? Used With: All units with LCI or BCI
installed. (if ENTER pressed above)
Possible values: YES/NO; BAS
Module Comm Failure
BAS/Network Comm Failure
_________________________ YES
1. Press the + or - key until the proper value is displayed.
2. Press the ENTER key to confirm this choice.
3. Press the NEXT key to advance the cursor.
4. Repeat steps 1 and 2 for the next value.
5. Press the NEXT key until the following screen is displayed
(if applicable).
Assignment Submenu - BAS/Network Alarms Used With: All units with Return
Fan installed. (if "Any Active
Diagnostic" is not selected above)
Press ENTER to Review or Adjust
1. Pressing the NEXT key will bypass this section.
Assign Diagnostic to Alarm Output? Used With: All units with Return
Fan installed. (if ENTER pressed
above)
Possible values: YES/NO
(IntelliPak II only); MPM
Communications Failure, Auto Reset
Return Pressure Limit, Manual Reset
Return Pressure Limit, Rtrn Plenum
Press Sensor Failure, Energy
Recovery Wheel Proof Failure,
Lvg Recovery Exh Temp Sensor Fail,
Comm Fail, Auto reset Return press.
limit, Man limit, Retorn plen. press.
failure.
_________________________ YES
1. Press the + or - key until the proper value is displayed.
2. Press the ENTER key to confirm this choice.
3. Press the NEXT key to advance the cursor.
4. Repeat steps 1 and 2 for the next value.
5. Press the NEXT key until the following screen is displayed
(if applicable).
Note: Assigning "Yes" to an Alarm output definition means that if
the assigned diagnostic is present, the RTM alarm output
will be energized.