179
Parameter
Function
Unit
Default
value
Range
Effective
Suitable
mode
Reference
chapter
02: Input positive signal
from SI2 terminal.
03: Input positive signal
from SI3 terminal.
04: Input positive signal
from SI4 terminal.
10: Set the signal to always
be "valid".
11: Inverse signal is input
from SI1 terminal.
12: Inverse signal is input
from SI2 terminal.
13: Inverse signal is input
from SI3 terminal.
14: Inverse signal is input
from SI4 terminal.
P5-20.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|5|6|7|
8|9|10
5.8.4.1
P5-21.0~1
/P-CON proportion action
instruction
-
00
0~ff
1|2|3|4|5|6|7|
8|9|10
5.8.6.1
P5-21.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|5|6|7|
8|9|10
5.8.4.1
P5-22.0~1
/P-OT: Forbidden forward
driving
-
03
0~ff
1|2|3|4|5|6|7|
8|9|10
5.2.4
P5-22.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|5|6|7|
8|9|10
5.8.4.1
P5-23.0~1
/N-OT: forbidden reverse
driving
-
04
0~ff
1|2|3|4|5|6|7|
8|9|10
5.2.4
P5-23.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|5|6|7|
8|9|10
5.8.4.1
P5-24.0~1
/ALM-RST: alarm clear
-
02
0~ff
1|2|3|4|5|6|7|
8|9|10
5.8.6.2
P5-24.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|5|6|7|
8|9|10
5.8.4.1
P5-25.0~1
/P-CL
External Torque
Limitation at Forward
Rotation Side
-
00
0~ff
1|2|3|4|5|6|7|
8|9|10
5.8.2
P5-25.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|5|6|7|
8|9|10
5.8.4.1
P5-26.0~1
/N-CL
External Torque
Limitation at Reverse
Rotation Side
-
00
0~ff
1|2|3|4|5|6|7|
8|9|10
5.8.2
P5-26.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|5|6|7|
8|9|10
5.8.4.1
P5-27.0~1
/SPD-D: Internal Speed
Direction Selection
-
00
0~ff
1|2|3|4|7
5.4.2
P5-27.2
SI terminal filtering time
ms
0
0~f
1|2|3|4|7
5.8.4.1
P5-28.0~1
/SPD-A: Internal Setting
Speed Selection
-
00
0~ff
3|5
5.4.2
P5-28.2
SI terminal filtering time
ms
0
0~f
3|5
5.8.4.1
P5-29.0~1
/SPD-B: Internal Setting
Speed Selection
-
00
0~ff
3|5
5.4.2
P5-29.2
SI terminal filtering time
ms
0
0~f
3|5
5.8.4.1
P5-30.0~1
/C-SEL: control mode
selection
-
00
0~ff
1|2|3|4|5|6|7|
8|9|10
5.1.2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5F Series and is the answer not in the manual?

Xinje DS5F Series Specifications

General IconGeneral
BrandXinje
ModelDS5F Series
CategoryServo Drives
LanguageEnglish

Related product manuals