• 409 Glass Cleaner
• Windex Blue
Harmful Ingredients
The following chemicals are known to damage the plastics on the device and should not come in contact with
the device: acetone; ketones; ethers; aromatic and chlorinated hydrocarbons; acqueous or alcoholic alkaline
solutions; ethanolamine; toluene; trichloroethylene; benzene; carbolic acid and TB-lysoform.
Many vinyl gloves contain phthalate additives, which are often not recommended for medical use and are
known to be harmful to the housing of the device.
Cleaners that are not approved include:
• Clorox Disinfecting Wipes
• Hydrogen Peroxide Cleaners
• Bleach Products.
Device Cleaning Instructions
Do not apply liquid directly to the device. Dampen a soft cloth or use pre-moistened wipes. Do not wrap the
device in the cloth or wipe, but gently wipe the unit. Be careful not to let liquid pool around the display window
or other places. Allow the unit to air dry before use.
NOTE: For thorough cleaning, it is recommended to first remove all accessory attachments, such as hand straps or cradle
cups, from the mobile device and to clean them separately.
Special Cleaning Notes
The device should not be handled while wearing vinyl gloves containing phthalates, or before hands are
washed to remove contaminant residue after gloves are removed.
If products containing any of the harmful ingredients listed above are used prior to handling the device, such as
hand sanitizer that contain ethanolamine, hands must be completely dry before handling the device to prevent
damage to the device.
IMPORTANT: If the battery connectors are exposed to cleaning agents, thoroughly wipe off as much of the chemical as
possible and clean with an alcohol wipe. It is also recommended to install the battery in the terminal prior to cleaning and
disinfecting the device to help minimize buildup on the connectors.
When using cleaning/disinfectant agents on the device, it is important to follow the directions prescribed by the
cleaning/disinfectant agent manufacturer.
Cleaning Materials Required
• Alcohol wipes
• Lens tissue
• Cotton-tipped applicators
• Isopropyl alcohol
• Can of compressed air with a tube.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra PS20 Series and is the answer not in the manual?

Zebra PS20 Series Specifications

General IconGeneral
BrandZebra
ModelPS20 Series
CategoryHandhelds
LanguageEnglish

Related product manuals