with IRC5’s enabling device chain is above 55 years. See safety related
performance for the enabling device chain below.
Performance of IRC5 original enabling device chain
The safety-related performance of the enabling device chain, without the external
enabling device, is as follows:
• MTTF
d
for IRC5 enabling device chain is 80 years.
• IRC5’s enabling device chain’s calculated average probability of dangerous
failure per hour (PFH
d
) is 6.62x10E-08.
• IRC5’s enabling device chain’s design and structure is category 3.
• IRC5’s enabling device chain’s Diagnostic Coverage is medium (90% < DCavg
< 99%).
• The Common Cause Failure (CCF) is met according to the standard
requirements.
Product manual - IRC5 Compact 103
3HAC047138-001 Revision: G
© Copyright 2009-2017 ABB. All rights reserved.
2 Installation and commissioning
2.11.2 Installation of external enabling device
Continued