2.6.5 Grounding
Location
Note
The whole cabinet ground is connected to the XP0.PE point.
xx1700000507
Description
XP0.1 Power llineA
XP0.PE GroundingB
XP0.2 Zero lineC
Required equipment
NoteEquipment
Mains connection cable (single phase)
See Circuit diagrams on page 217.Circuit diagram
Connecting ground controller
The following procedure describes how to connect the mains power to the controller.
Action
Connect single-phase power supply and PE wire to the XP0 connector.1
Product manual - IRC5 Compact 73
3HAC047138-001 Revision: G
© Copyright 2009-2017 ABB. All rights reserved.
2 Installation and commissioning
2.6.5 Grounding