Parameter 5-68 Pulse Output Max Freq #30/6
Table 380: Parameter 5-68 Pulse Output Max Freq #30/6
5-68 Pulse Output Max Freq #30/6
Default value: Size related
Parameter type: Range, 0 - 110000 Hz
Setup: All setups
Conversion index: 0
Data type: Uint32
Change during operation: True
N O T I C E
This parameter cannot be changed while the motor is running.
Set the maximum frequency on terminal X30/6 referring to the output variable selected in parameter 5-66 Terminal X30/6 Pulse Out-
put Variable. This parameter is active when VLT® General Purpose I/O MCB 101 is installed in the drive.
5.6.7 5-7* 24 V Encoder Input
Connect the 24 V encoder to terminal 12 (24 V DC supply), terminal 32 (channel A), terminal 33 (channel B), and terminal 20 (GND).
The digital inputs 32/33 are active for encoder inputs when [1] 24 V encoder is selected in parameter 1-02 Flux Motor Feedback Source
and parameter 7-00 Speed PID Feedback Source. The encoder used is a dual-channel (A and B) 24 V type. Maximum input frequency:
110 kHz.
Encoder connection to the drive
24 V incremental encoder. Maximum cable length is 5 m (16.4 ft).
e30ba090.12
+24 V DC
A
B
GND
13
12
18
37
3227
19
29
33
20
24 V or 10–30 V encoder
Illustration 67: Encoder Connection
AU275636650261en-000101 / 130R0334 | 225Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals