Table 658: Parameter 12-85 ACD Last Conflict
Parameter type: Range, 0 - 2147483647
Change during operation: True
The name of the IP address causing the most recent address conflict.
Parameter 12-89 Transparent Socket Channel Port
Table 659: Parameter 12-89 Transparent Socket Channel Port
12-89 Transparent Socket Channel Port
Default value: Size related
Parameter type: Range, size related
Change during operation: True
Configures the TCP port number for the transient socket channel. This enables FC telegrams to be sent transiently on Ethernet via
TCP. The default value of 4000.0 indicates disabled.
5.12.10 12-9* Advanced Ethernet Services
Parameter 12-90 Cable Diagnostic
Table 660: Parameter 12-90 Cable Diagnostic
Default value: [0] Disabled
Change during operation: True
Enables/disables advanced cable diagnosis function. If enabled, the distance to cable errors can be read out in parameter 12-93 Ca-
ble Error Length. The parameter resumes to the default setting [0] Disable after the diagnostics have finished.
N O T I C E
The cable diagnostics function is only issued on ports where there is no link (see parameter 12-10 Link Status).
12-91 Auto Cross Over
Table 661: Parameter 12-91 Auto Cross Over
Default value: [1] Enabled
Change during operation: True