feedback source in parameter 1-02 Flux Motor Feedback Source, parameter 7-00 Speed PID Feedback Source, or parameter 7-90 Position
PI Feedback Source.
Parameter 17-68 Raw Abs. Pos. Low
Table 939: Parameter 17-68 Raw Abs. Pos. Low
Parameter type: Range, 0 - 2147483647
Change during operation: False
N O T I C E
This parameter is only available with software version 48.9X.
Shows the least significant 32 bits of the position value read from an absolute encoder connected to VLT® Encoder Input MCB 102.
MCB 102 must be selected as feedback source in parameter 1-02 Flux Motor Feedback Source, parameter 7-00 Speed PID Feedback
Source, or parameter 7-90 Position PI Feedback Source.
Parameter 17-69 Raw Abs. Pos. High
Table 940: Parameter 17-69 Raw Abs. Pos. High
Parameter type: Range, 0 - 2147483647
Change during operation: False
N O T I C E
This parameter is only available with software version 48.9X.
Shows the most significant 32 bits of the position value read from an absolute encoder connected to VLT® Encoder Input MCB 102.
MCB 102 must be selected as feedback source in parameter 1-02 Flux Motor Feedback Source, parameter 7-00 Speed PID Feedback
Source, or parameter 7-90 Position PI Feedback Source.
5.17.7 17-7* Position Scaling
Parameters in this group define how the drive scales and handles the position values.
Parameter 17-70 Position Unit
Table 941: Parameter 17-70 Position Unit
Change during operation: False
Select the physical unit for showing the position values on the LCP.