5.4.3 3-2* References II
Parameter 3-20 Preset Target
Table 204: Parameter 3-20 Preset Target
3-20 Preset Target
Default value: 0 Custom- ReadoutU-
nit2
Parameter type: Range, -2147483648 - 2147483647
CustomReadoutUnit2, Array [8]
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Set up to 8 target positions. Select from the 8 preset positions using digital inputs or the fieldbus control word.
Parameter 3-21 Touch Target
Table 205: Parameter 3-21 Touch Target
3-21 Touch Target
Default value: 0 Custom- ReadoutU-
nit2
Parameter type: Range, -2147483648 - 2147483647
CustomReadoutUnit2, Array [8]
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
2147483647 = Latch Only. With Latch Only actual position of touch sensor is latched and updated in parameter 18-25 Latched Actual
Pos but no positioning is executed. Enter the target position in touch probe positioning mode. This parameter defines the distance
from the detection event of the touch probe sensor to the final target position in position units.
Parameter 3-22 Master Scale Numerator
Table 206: Parameter 3-22 Master Scale Numerator
3-22 Master Scale Numerator
Default value: 1
Parameter type: Range, -2147483648 - 2147483647
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Parameter 3-22 Master Scale Numerator and parameter 3-23 Master Scale Denominator define the gear ratio between the master and
the follower in synchronization mode.
Masterrevolutions = 
Par . 3 − 22
Par . 3 − 23
 × Followerrevolutions
Parameter 3-23 Master Scale Denominator
Table 207: Parameter 3-23 Master Scale Denominator
3-23 Master Scale Denominator
Default value: 1
Parameter type: Range, -2147483648 - 2147483647
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
AU275636650261en-000101 / 130R0334136 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals