Parameter 17-71 Position Unit Scale
Table 942: Parameter 17-71 Position Unit Scale
17-71 Position Unit Scale
Default value: 0
Parameter type: Range, -3 - 3, Array [2]
Setup: All setups
Conversion index: 0
Data type: Int8
Change during operation: False
Enter the scaling factor for the position values. The scaling function multiplies the readout values by 10
x
, where x is the value of this
parameter. For example, if x = 2, the value 5 is shown as 500. The elements of the array are:
Index 0 is the scaling factor for readout and settings of position values in parameters or in a fieldbus. Index 1 contains excep-
tions.
Index 1 is the scaling factor for readout of position error (parameter 16-08 Position Error) and for the value of parameter 3-08 On
Target Window.
Parameter 17-72 Position Unit Numerator
Table 943: Parameter 17-72 Position Unit Numerator
17-72 Position Unit Numerator
Default value: 1024
Parameter type: Range, -2147483648 - 2147483647
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: False
This parameter is the numerator in the equation which defines the relation between 1 motor revolution and physical movement of
machine.
Positionunit =
Par . 17 − 72
Par . 17 − 73
× Motorrevolutions
Example: Consider a turn table application. The motor makes 10 revolutions when the table makes 1 revolution. The position unit is
a degree. For this setup, enter the following values:
Parameter 17-72 Position Unit Numerator = 360
Parameter 17-73 Position Unit Denominator = 10
Set the physical unit for position values in parameter 17-70 Position Unit.
Parameter 17-73 Position Unit Denominator
Table 944: Parameter 17-73 Position Unit Denominator
17-73 Position Unit Denominator
Default value: 1
Parameter type: Range, -2147483648 - 2147483647
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: False
See parameter 17-72 Position Unit Numerator.
AU275636650261en-000101 / 130R0334526 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals