Parameter 17-74 Position Offset
Table 945: Parameter 17-74 Position Offset
17-74 Position Offset
Default value: 0
Parameter type: Range, -2147483648 - 2147483647
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: False
Enter the absolute encoder position offset. Use this parameter to adjust the 0 position of the encoder without physically moving the
encoder. Set the physical unit for position values in parameter 17-70 Position Unit.
Parameter 17-75 Position Recovery at Power-up
Table 946: Parameter 17-75 Position Recovery at Power-up
17-75 Position Recovery at Power-up
Default value: [0] Off
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
N O T I C E
This parameter is only available with software version 48.XX.
Select the actual position after power-up when using open loop or incremental encoders.
Option
Name
Description
[0]*
Off
The actual position is 0 after power-up.
[1]
On
This drive stores the actual position at power-down and uses it as the actual position when powered up.
Parameter 17-76 Position Axis Mode
Table 947: Parameter 17-76 Position Axis Mode
17-76 Position Axis Mode
Default value: [0] Linear axis
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
N O T I C E
This parameter is only available with software version 48.XX.
Select the axis type for position counting.
Op-
tion
Name
Description
[0]*
Linear axis
The motion is within a position range defined by parameter 3-06 Minimum Position and parameter 3-07
Maximum Position.
[1]
Rotary 0 -
Max
Continuous motion, where the position changes between 0 and parameter 3-07 Maximum Position.
When passing the maximum position, the reading restarts from 0.
[2]
Rotary min -
max
N O T I C E
This option is available only with software version 48.20 and newer.
AU275636650261en-000101 / 130R0334 | 527Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals