View the power section. The readout is identical to the drive power field of the type code definition, characters 7–10.
Parameter 15-42 Voltage
Table 787: Parameter 15-42 Voltage
15-42 Voltage
Default value: 0
Parameter type: Range, 0 - 20
Setup: All setups
Conversion index: 0
Data type: VisStr[20]
Change during operation: False
View the voltage. The readout is identical to the drive power field of the type code definition, characters 11-12.
Parameter 15-43 Software Version
Table 788: Parameter 15-43 Software Version
15-43 Software Version
Default value: 0
Parameter type: Range, 0 - 5
Setup: All setups
Conversion index: 0
Data type: VisStr[5]
Change during operation: False
View the combined SW version (or package version) consisting of power SW and control SW.
Parameter 15-44 Ordered Typecode String
Table 789: Parameter 15-44 Ordered Typecode String
15-44 Ordered Typecode String
Default value: 0
Parameter type: Range, 0 - 40
Setup: All setups
Conversion index: 0
Data type: VisStr[40]
Change during operation: False
View the type code string used for reordering the drive in its original configuration.
Parameter 15-45 Actual Typecode String
Table 790: Parameter 15-45 Actual Typecode String
15-45 Actual Typecode String
Default value: 0
Parameter type: Range, 0 - 40
Setup: All setups
Conversion index: 0
Data type: VisStr[40]
Change during operation: False
View the actual type code string.
Parameter 15-46 Frequency Converter Ordering No
Table 791: Parameter 15-46 Frequency Converter Ordering No
15-46 Frequency Converter Ordering No
Default value: 0
Parameter type: Range, 0 - 8
Setup: All setups
Conversion index: 0
Data type: VisStr[8]
Change during operation: False
View the 8-digit code number used for reordering the drive in its original configuration. To restore the order number after the pow-
er card exchange, see parameter 14-29 Service Code.
Parameter 15-47 Power Card Ordering No
Table 792: Parameter 15-47 Power Card Ordering No
15-47 Power Card Ordering No
Default value: 0
Parameter type: Range, 0 - 8
Setup: All setups
Conversion index: 0
Data type: VisStr[8]
Change during operation: False
AU275636650261en-000101 / 130R0334490 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals