Option
Name
Description
[4]
Bus: No access
No access to parameters is allowed via fieldbus and/or FC standard bus.
[5]
All: Read only
Read-only function for parameters on LCP, fieldbus, or FC standard bus.
[6]
All: No access
No access from LCP, fieldbus, or FC standard bus is allowed.
If [0] Full access is selected, parameter 0-60 Main Menu Password, parameter 0-65 Personal Menu Password, and parameter 0-66 Access
to Personal Menu w/o Password are ignored.
N O T I C E
A more complex password protection is available for OEMs upon request.
Parameter 0-65 Personal Menu Password
Table 38: Parameter 0-65 Personal Menu Password
0-65 Personal Menu Password
Default value: 200
Parameter type: Range, -9999 - 9999
Setup: 1 setup
Conversion index: 0
Data type: Int16
Change during operation: True
Define the password for access to the Quick Menu via the [Quick Menu] key. If parameter 0-66 Access to Personal Menu w/o Password
is set to [0] Full access, this parameter is ignored.
Parameter 0-66 Access to Personal Menu w/o Password
Table 39: Parameter 0-66 Access to Personal Menu w/o Password
0-66 Access to Personal Menu w/o Password
Default value: [0] Full access
Parameter type: Option
Setup: 1 setup
Conversion index: –
Data type: Uint8
Change during operation: True
If parameter 0-61 Access to Main Menu w/o Password is set to [0] Full access, then this parameter is ignored.
Option
Name
Description
[0]*
Full access
Disables password defined in parameter 0-65 Personal Menu Password.
[1]
LCP: Read only
Prevent unauthorized editing of Quick Menu parameters.
[3]
Bus: Read only
Read-only functions for Quick Menu parameters on fieldbus and/or FC standard bus.
[5]
All: Read only
Read-only function for Quick Menu parameters on LCP, fieldbus, or FC standard bus.
Parameter 0-67 Bus Password Access
Table 40: Parameter 0-67 Bus Password Access
0-67 Bus Password Access
Default value: 0
Parameter type: Range, 0 - 9999
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Use this parameter to unlock the drive via fieldbus or VLT® Motion Control Tool MCT 10.
AU275636650261en-000101 / 130R033458 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals