830 Configuring Data Center Bridging Features
ports that are directly connected to Converged Network Adapters (CNAs) on
individual workstations (ports 1–3 on each switch) are designated as DCBx
default auto-downstream ports.
To configure FIP snooping:
1
Enter global configuration mode and enable FIP snooping on the switch.
console#configure
console(config)#feature fip-snooping
2
Create VLAN 100. This command also enters the VLAN configuration
mode for VLAN 100.
console(config)#vlan 100
console(config-vlan100)#fip-snooping enable
console(config-vlan100)#exit
3
Enter Interface Configuration mode for ports 1, 2, 3, 16, and 17 on both
switches in the stack.
console(config)#interface range te1/0/1-
3,te1/0/16-17,te2/0/1-3,te2/0/16-17
4
Enable VLAN tagging to allow the ports to carry
802.1p priority values
through the network.